SLS switch

Hager HTN340E SLS switch 3P E-40A DIN rail
Hager HTN340E SLS switch 3P E-40A DIN rail
Out-of-Stock
SLS switch 3 polig E-characteristic 40A for DIN rail mounting. SH switch according to E-DIN VDE 0641-21 and standard DIN 43 880 size 2. SLS in 1- or 3-pole design, one-pole switching, with separate contact position display. For direct mounting on a hat rail. The standard (no suggestions) allows the following limitations: for the customer against unintentional or intentional switching; for the installer with a padlock when working in the plant; for the VNB with plombier wire, padlock or special key.
Hager HTN350E SLS switch 3P E-50A DIN rail
Hager HTN350E SLS switch 3P E-50A DIN rail
Out-of-Stock
SLS switch 3 polig E-characteristic 50A for DIN rail mounting. SH switch according to E-DIN WDE 0641-21 and standard DIN 43 880 size 2. SLS in 1- or 3-pole design, one-pole switching, with separate contact position display. For direct mounting on a hat rail. The standard (no suggestions) allows the following limitations: for the customer against unintentional or intentional switching; for the installer with a padlock when working in the plant; for the WNB with plombier wire, padlock or special key.
Hager HTN335E SLS switch 3P E-35A DIN rail
Hager HTN335E SLS switch 3P E-35A DIN rail
Out-of-Stock
SLS switch 3 polig E-Characteristic 35A for DIN rail mounting. SH switch according to E-DIN WDE 0641-21 and standard DIN 43 880 size 2. SLS in 1- or 3-pole design, one-pole switching, with separate contact position display. For direct mounting on a hat rail. The standard (no suggestions) allows the following limitations: for the customer against unintentional or intentional switching; for the installer with a padlock when working in the plant; for the WNB with plombier wire, padlock or special key.
Hager HTN363E SLS switch 3P E-63A DIN rail
Hager HTN363E SLS switch 3P E-63A DIN rail
2-7 days
SLS switch 3 polig E-Characteristic 63A for DIN rail mounting. SH switch according to E-DIN VDE 0641-21 and standard DIN 43 880 size 2. SLS in 1- or 3-pole design, one-pole switching, with separate contact position display. For direct mounting on a hat rail. The standard (no suggestions) allows the following limitations: for the customer against unintentional or intentional switching; for the installer with a padlock when working in the plant; for the VNB with plombier wire, padlock or special key.
Hager HTS335E SLS switch 3P E-35A busbar QC
Hager HTS335E SLS switch 3P E-35A busbar QC
2-7 days
SLS switch 3 polig E-characteristic 35A for busbar Quickconnect. SH switch according to E-DIN WDE 0641-21 and standard DIN 43 880 Size 6. SLS in different pole shape, one-pole switching, with separate contact position display. Plug contacting for direct busbar mounting. The standard multi-function closure allows the following closures: for the customer against unintentional or misconductive switching, for the installer with a padlock when working in the plant, for the WNB with plomb wire, padlock or special key.
Hager HTS325E SLS switch 3P E-25A busbar QC
Hager HTS325E SLS switch 3P E-25A busbar QC
2-7 days
SLS switch 3 polig E-characteristic 25A for busbar Quickconnect. SH switch according to E-DIN WDE 0641-21 and standard DIN 43 880 Size 6. SLS in different pole shape, one-pole switching, with separate contact position display. Plug contacting for direct busbar mounting. The standard multi-function closure allows the following closures: for the customer against unintentional or misconductive switching, for the installer with a padlock when working in the plant, for the WNB with plomb wire, padlock or special key.
Hager HTS340E SLS switch 3P E-40A busbar QC
Hager HTS340E SLS switch 3P E-40A busbar QC
2-7 days
SLS switch 3 polig E-characteristic 40A for busbar Quickconnect. SH switch according to E-DIN WDE 0641-21 and standard DIN 43 880 Size 6. SLS in different pole shape, one-pole switching, with separate contact position display. Plug contacting for direct busbar mounting. The standard multi-function closure allows the following closures: for the customer against unintentional or misconductive switching, for the installer with a padlock when working in the plant, for the WNB with plomb wire, padlock or special key.
Hager HTN325E SLS switch 3P E-25A DIN rail
Hager HTN325E SLS switch 3P E-25A DIN rail
2-10 days
SLS switch 3 polig E-characteristic 25A for DIN rail mounting. SH switch according to E-DIN WDE 0641-21 and standard DIN 43 880 size 2. SLS in 1- or 3-pole design, one-pole switching, with separate contact position display. For direct mounting on a hat rail. The standard (no suggestions) allows the following limitations: for the customer against unintentional or intentional switching; for the installer with a padlock when working in the plant; for the WNB with plombier wire, padlock or special key.
Hager HTS350E SLS switch 3P E-50A busbar QC
Hager HTS350E SLS switch 3P E-50A busbar QC
2-7 days
SLS switch 3 polig E-characteristic 50A for busbar Quickconnect. SH switch according to E-DIN WDE 0641-21 and standard DIN 43 880 Size 6. SLS in different pole shape, one-pole switching, with separate contact position display. Plug contacting for direct busbar mounting. The standard multi-function closure allows the following closures: for the customer against unintentional or misconductive switching, for the installer with a padlock when working in the plant, for the WNB with plomb wire, padlock or special key.
Hager HTS363E SLS switch 3P E-63A busbar QC
Hager HTS363E SLS switch 3P E-63A busbar QC
2-7 days
SLS switch 3 polig E-characteristic 63A for busbar Quickconnect. SH switch according to E-DIN WDE 0641-21 and standard DIN 43 880 Size 6. SLS in different pole shape, one-pole switching, with separate contact position display. Plug contacting for direct busbar mounting. The standard multi-function closure allows the following closures: for the customer against unintentional or misconductive switching, for the installer with a padlock when working in the plant, for the WNB with plomb wire, padlock or special key.
Hager HTS135E SLS switch 1P E-35A busbar QC
Hager HTS135E SLS switch 1P E-35A busbar QC
2-7 days
SLS switch 1 polig E-characteristic 35A for busbar Quickconnect. SH switch according to E-DIN WDE 0641-21 and standard DIN 43 880 Size 6. SLS in different pole shape, one-pole switching, with separate contact position display. Plug contacting for direct busbar mounting. The standard multi-function closure allows the following closures: for the customer against unintentional or misconductive switching, for the installer with a padlock when working in the plant, for the WNB with plomb wire, padlock or special key.
Hager HTN135E SLS switch 1P E-35A DIN rail
Hager HTN135E SLS switch 1P E-35A DIN rail
2-7 days
SLS switch 1 polig E-characteristic 35A for DIN rail mounting. SH switch according to E-DIN WDE 0641-21 and standard DIN 43 880 size 2. SLS in 1- or 3-pole design, one-pole switching, with separate contact position display. For direct mounting on a hat rail. The standard (no suggestions) allows the following limitations: for the customer against unintentional or intentional switching; for the installer with a padlock when working in the plant; for the WNB with plombier wire, padlock or special key.
Hager HTS163E SLS switch 1P E-63A busbar L2
Hager HTS163E SLS switch 1P E-63A busbar L2
2-7 days
SLS switch 1 polig E-characteristic 63A for busbar Quickconnect. SH switch according to E-DIN WDE 0641-21 and standard DIN 43 880 Baugroesse 6. SLS in different pole shape, one-pole switching, with separate contact position display. Plug contacting for direct busbar mounting. The standard multifunction closure allows the following locks: 1.for the customer to switch against unintentional or intentional, 2.for the installer with a padlock when working in the system, 3.for the WNB with plomb wire, padlock or special key.
Hager HTN150E SLS switch 1P E-50A DIN rail
Hager HTN150E SLS switch 1P E-50A DIN rail
2-7 days
SLS switch 1 polig E-characteristic 50A for DIN rail mounting. SH switch according to E-DIN WDE 0641-21 and standard DIN 43 880 size 2. SLS in 1- or 3-pole design, one-pole switching, with separate contact position display. For direct mounting on a hat rail. The standard (no suggestions) allows the following limitations: for the customer against unintentional or intentional switching; for the installer with a padlock when working in the plant; for the WNB with plombier wire, padlock or special key.