Eaton AFDD-16/2/B/003-A fire protection switch, fault arc protection device 187204
2-10 Tage
Basic function
Fire switch
Pole
2-pole
Trigger characteristic
B
Application
Switching devices for housing and purpose construction
Rated current
In
A
16
Measurement switching capacity according to IEC/EN 60898-1
:
10
Measurement switching capacity according to IEC/EN 61009
:
10
Measurement short-circuit strength
Ic)
:
10
Measurement error current
IBY DN
A
0,03 %
Type
Type A
Redemption
A
not delayed
Type of waste
ZV-SS
Product range
OFDD
Sensitivity
electrification
Impact resistance
conditional shock resistant 250 A
Technical data
Electric
Finished
IEC 62606IEC 61009
Current test marks
according to the following conditions:
Limits of operating voltage
Test circuit
BY AC
170 - 264
Sensitivity
electrification
Measurement short-circuit strength
Ic)
:
10
Life
electrical
Circuit games
4000
mechanical
Circuit games
20000
Mechanical
Cap dimensions
mm
45
Approval
mm
80
Installation width
mm
54 (3TH)
Assembly
Tristable locking slide allows removal from an existing composite.
Type of protection
IP20 switchIP40 installed
Clamps up and down
Mouth/Lift clamps
Clamp protection
Contact protection according to WBG4, ÖVE-EN 6
Material thickness
mm
0.8 - 2
permissible ambient temperature range
C
-25 - +40
permissible storage or. Transport temperature
C
-35 - +60
Climate resistance
in accordance with IEC/EN 61009
Contact position indicator
red / green
Fire switch
Pole
2-pole
Trigger characteristic
B
Application
Switching devices for housing and purpose construction
Rated current
In
A
16
Measurement switching capacity according to IEC/EN 60898-1
:
10
Measurement switching capacity according to IEC/EN 61009
:
10
Measurement short-circuit strength
Ic)
:
10
Measurement error current
IBY DN
A
0,03 %
Type
Type A
Redemption
A
not delayed
Type of waste
ZV-SS
Product range
OFDD
Sensitivity
electrification
Impact resistance
conditional shock resistant 250 A
Technical data
Electric
Finished
IEC 62606IEC 61009
Current test marks
according to the following conditions:
Limits of operating voltage
Test circuit
BY AC
170 - 264
Sensitivity
electrification
Measurement short-circuit strength
Ic)
:
10
Life
electrical
Circuit games
4000
mechanical
Circuit games
20000
Mechanical
Cap dimensions
mm
45
Approval
mm
80
Installation width
mm
54 (3TH)
Assembly
Tristable locking slide allows removal from an existing composite.
Type of protection
IP20 switchIP40 installed
Clamps up and down
Mouth/Lift clamps
Clamp protection
Contact protection according to WBG4, ÖVE-EN 6
Material thickness
mm
0.8 - 2
permissible ambient temperature range
C
-25 - +40
permissible storage or. Transport temperature
C
-35 - +60
Climate resistance
in accordance with IEC/EN 61009
Contact position indicator
red / green
€117.25