Hager BY MS

Hager MBN525 LS switch 1p+N, B-25A, 6kA circuit breaker 1polig+N 6kA B-characteristics 25A 2 modules
Hager MBN525 LS switch 1p+N, B-25A, 6kA circuit breaker 1polig+N 6kA B-characteristics 25A 2 modules
Out-of-Stock
Circuit breaker 1polig+N 6kA B-Characteristic 25A 2 Modules Circuit breaker according to DIN VDE 0641 part 11/8.92 , contact protection IP2x according to DIN VDE 0106 part 100 with VDE characters. LS with time-delayed thermal exhaust for overload protection and electromagnetic exhaust for short-circuit protection. Suitable for retrofit installation of additional equipment. Possibility of marking directly on the device and individual removal from the phase rail composite by unlocking the quick attachment of the hat rails.Rated current:25 ATrigger characteristic:BNominal deactivation capacity:6Number of poles:2 PNumber of modules:2AC voltage:OF 230/400 VInsulation voltage:500 VFrequency:50/60 HzConnection type:Screw technologyTorque:2.8 NmTotal power loss under rated current:6 WDevice life, electrical switching games:4000Machine life mechanical switching games:20000Operating temperature:-25 to 60 °CStorage temperature:-25 to 80 °CHeight installed product:83 mmWide installed product:35 mmDeep Installed Product:70 mm
Hager MBN513 LS switch 13A/1pol+N/B 6kA
Hager MBN513 LS switch 13A/1pol+N/B 6kA
2-5 Tage
Circuit breaker 1polig+N 6kA B-Characteristic 13A 2 Modules Circuit breaker according to DIN VDE 0641 part 11/8.92 , contact protection IP2x according to DIN VDE 0106 part 100 with VDE characters. LS with time-delayed thermal exhaust for overload protection and electromagnetic exhaust for short-circuit protection. Suitable for retrofit installation of additional equipment. Possibility of marking directly on the device and individual removal from the phase rail composite by unlocking the quick attachment of the hat rails. Rated current: 13 ATrigger characteristic: BNominal shutdown capacity: 6 kANumber of poles: 2 PNumber of modules: 2AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50/60 HzConnection type: screw technologyTorque: 2,8NmTotal loss power under rated current: 4.6 WDevice life, electrical switching games: 4000Machine life mechanical switching games: 20000Operating temperature: -25 to 60 °CStorage temperature: -25 to 80 °CHeight installed product: 83 mmWide installed product: 35 mmDeep installed product: 70 mm
Hager MBN516 LS switch 16A/1pol+N/B 6kA
Hager MBN516 LS switch 16A/1pol+N/B 6kA
2-5 Tage
Circuit breaker 1polig+N 6kA B-Characteristic 16A 2 Modules Circuit breaker according to DIN VDE 0641 part 11/8.92 , contact protection IP2x according to DIN VDE 0106 part 100 with VDE characters. LS with time-delayed thermal exhaust for overload protection and electromagnetic exhaust for short-circuit protection. Suitable for retrofit installation of additional equipment. Possibility of marking directly on the device and individual removal from the phase rail composite by unlocking the quick attachment of the hat rails. Rated current: 16 ATrigger characteristic: BNominal shutdown capacity: 6 kANumber of poles: 2 PNumber of modules: 2AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50/60 HzConnection type: screw technologyTorque: 2,8NmTotal loss power at rated current: 4.2 WDevice life, electrical switching games: 4000Machine life mechanical switching games: 20000Operating temperature: -25 to 60 °CStorage temperature: -25 to 80 °CHeight installed product: 83 mmWide installed product: 35 mmDeep installed product: 70 mm
Hager MBN113 LS switch 13A/1pol/B 6kA
Hager MBN113 LS switch 13A/1pol/B 6kA
2-5 days
Circuit breaker 1pole 6kA B-characteristic 13A 1 moduleCircuit breaker according to DIN VDE 0641 part 11/8.92 , contact protection IP2x according to DIN VDE 0106 part 100 with VDE characters. LS with time-delayed thermal exhaust for overload protection and electromagnetic exhaust for short-circuit protection. Suitable for retrofit installation of additional equipment. Possibility of marking directly on the device and individual removal from the phase rail composite by unlocking the quick attachment of the hat rails. Rated current: 13 ATrigger characteristic: BNominal shutdown capacity: 6 kANumber of poles: 1 PNumber of modules: 1AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50/60 HzConnection type: screw technologyTorque: 2,8NmTotal power loss under rated current: 2.2 WDevice life, electrical switching games: 4000Machine life mechanical switching games: 20000Operating temperature: -25 to 60 °CStorage temperature: -25 to 80 °CHeight installed product: 83 mmWide installed product: 17.5 mmDeep installed product: 70 mm
Hager MBN116 LS switch 16A/1pol/B 6kA
Hager MBN116 LS switch 16A/1pol/B 6kA
2-5 days
Circuit breaker 1pole 6kA B-characteristic 16A 1 module Circuit breaker according to DIN VDE 0641 part 11/8.92 , contact protection IP2x according to DIN VDE 0106 part 100 with VDE characters. LS with time-delayed thermal exhaust for overload protection and electromagnetic exhaust for short-circuit protection. Suitable for retrofit installation of additional equipment. Possibility of marking directly on the device and individual removal from the phase rail composite by unlocking the quick attachment of the hat rails. Rated current: 16 ATrigger characteristic: BNominal shutdown capacity: 6 kANumber of poles: 1 PNumber of modules: 1AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50/60 HzConnection type: screw technologyTorque: 2,8NmTotal loss power at rated current: 2.4 WDevice life, electrical switching games: 4000Machine life mechanical switching games: 20000Operating temperature: -25 to 60 °CStorage temperature: -25 to 80 °CHeight installed product: 83 mmWide installed product: 17.5 mmDeep installed product: 70 mm
Hager MBN616 LS switch 16A/3pol+N/B 6kA
Hager MBN616 LS switch 16A/3pol+N/B 6kA
2-5 days
3polig+N 6kA B-Characteristic 16A 4 Modules Circuit breaker according to DIN VDE 0641 part 11/8.92 , contact protection IP2x according to DIN VDE 0106 part 100 with VDE characters. LS with time-delayed thermal exhaust for overload protection and electromagnetic exhaust for short-circuit protection. Suitable for retrofit installation of additional equipment. Possibility of marking directly on the device and individual removal from the phase rail composite by unlocking the quick attachment of the hat rails. Rated current: 16 ATrigger characteristic: BNominal shutdown capacity: 6 kANumber of poles: 4 PNumber of modules: 4AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50/60 HzConnection type: screw technologyTorque: 2,8NmTotal loss power at rated current: 8.2 WDevice life, electrical switching games: 4000Machine life mechanical switching games: 20000Operating temperature: -25 to 60 °CStorage temperature: -25 to 80 °CHeight installed product: 83 mmWide installed product: 70 mmDeep installed product: 70 mm
Hager MBN316 LS switch 16A/3pol/B 6kA
Hager MBN316 LS switch 16A/3pol/B 6kA
2-5 days
3polig 6kA B-Characteristic 16A 3 Modules Circuit breaker according to DIN VDE 0641 part 11/8.92 , contact protection IP2x according to DIN VDE 0106 part 100 with VDE characters. LS with time-delayed thermal exhaust for overload protection and electromagnetic exhaust for short-circuit protection. Suitable for retrofit installation of additional equipment. Possibility of marking directly on the device and individual removal from the phase rail composite by unlocking the quick attachment of the hat rails. Rated current: 16 ATrigger characteristic: BNominal shutdown capacity: 6 kANumber of poles: 3 PNumber of modules: 3AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50/60 HzConnection type: screw technologyTorque: 2,8NmTotal loss power at rated current: 6.3 WDevice life, electrical switching games: 4000Machine life mechanical switching games: 20000Operating temperature: -25 to 60 °CStorage temperature: -25 to 80 °CHeight installed product: 83 mmWide installed product: 52.5 mmDeep installed product: 70 mm
Hager MBN506 LS switch 6A/1pol+N/B 6kA circuit breaker 1 polig+N B-characteristics 6A 2 modules
Hager MBN506 LS switch 6A/1pol+N/B 6kA circuit breaker 1 polig+N B-characteristics 6A 2 modules
2-5 days
Circuit breaker 1polig+N 6kA B-Characteristic 6A 2 modules circuit breaker according to DIN VDE 0641 part 11/8.92, IP2x contact protection according to DIN VDE 0106 part 100 with VDE characters. LS with time-reduced thermal Loose for overload protection and electromagnetic Loose for short-circuit protection. Suitable for retrofitting of additional equipment. marking option directly on the device and individual withdrawal from the phase rail composite Unlocking the quick-fit rail mounting. Rated current: 6 A Trigger characteristic: B Nominal shutdown capacity: 6 kA Number of poles: 2 P Number of modules: 2 Operating voltage AC current: 230/400 V Frequency: 50/60 Hz Connection type: screw technology
Hager MBN613 LS switch 13A/3pol+N/B 6kA
Hager MBN613 LS switch 13A/3pol+N/B 6kA
2-5 days
Circuit breaker 3polig+N 6kA B-Characteristic 13A 4 modules circuit breaker according to DIN VDE 0641 part 11/8.92 , contact protection IP2x according to DIN VDE 0106 part 100 with VDE characters. LS with time-delayed thermal exhaust for overload protection and electromagnetic exhaust for short-circuit protection. Suitable for retrofit installation of additional equipment. Possibility of marking directly on the device and individual removal from the phase rail composite by unlocking the quick attachment of the hat rails. Rated current: 13 ATrigger characteristic: BNominal shutdown capacity: 6 kANumber of poles: 4 PNumber of modules: 4AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50/60 HzConnection type: screw technologyTorque: 2,8NmTotal loss power at rated current: 6.7 WDevice life, electrical switching games: 4000Machine life mechanical switching games: 20000Operating temperature: -25 to 60 °CStorage temperature: -25 to 80 °CHeight installed product: 83 mmWide installed product: 70 mmDeep installed product: 70 mm
Hager MBN106 LS switch 6A/1pol/B circuit breaker 1 polig 6kA B-characteristic 6A 1 module
Hager MBN106 LS switch 6A/1pol/B circuit breaker 1 polig 6kA B-characteristic 6A 1 module
2-5 days
Rated current: 6 ATrigger characteristic: BNominal shutdown capacity: 6 kANumber of poles: 1 PNumber of modules: 1AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50/60 HzConnection type: screw technologyTorque: 2,8NmTotal loss power at rated current: 1.3 WDevice life, electrical switching games: 4000Machine life mechanical switching games: 20000Operating temperature: -25 to 60 °CStorage temperature: -25 to 80 °CHeight installed product: 83 mmWide installed product: 17.5 mmDeep installed product: 70 mm
Hager MBN625 LS switch 25A/3pol+N/B 6kA
Hager MBN625 LS switch 25A/3pol+N/B 6kA
2-5 days
3polig+N 6kA B-Characteristic 25A 4 ModulesCircuit breaker according to DIN VDE 0641 part 11/8.92 , contact protection IP2x according to DIN VDE 0106 part 100 with VDE characters. LS with time-delayed thermal exhaust for overload protection and electromagnetic exhaust for short-circuit protection. Suitable for retrofit installation of additional equipment. Possibility of marking directly on the device and individual removal from the phase rail composite by unlocking the quick attachment of the hat rails. Rated current: 25 ATrigger characteristic: BNominal shutdown capacity: 6 kANumber of poles: 4 PNumber of modules: 4AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50/60 HzConnection type: screw technologyTorque: 2,8NmTotal loss power at rated current: 10,1 WDevice life, electrical switching games: 4000Machine life mechanical switching games: 20000Operating temperature: -25 to 60 °CStorage temperature: -25 to 80 °CHeight installed product: 83 mmWide installed product: 70 mmDeep installed product: 70 mm
Hager MBN313 LS switch 13A/3pol/B 6kA
Hager MBN313 LS switch 13A/3pol/B 6kA
2-8 days
Circuit breaker 3polig 6kA B-Characteristic 13A 3 Modules Circuit breaker according to DIN VDE 0641 part 11/8.92 , contact protection IP2x according to DIN VDE 0106 part 100 with VDE characters. LS with time-delayed thermal exhaust for overload protection and electromagnetic exhaust for short-circuit protection. Suitable for retrofit installation of additional equipment. Possibility of marking directly on the device and individual removal from the phase rail composite by unlocking the quick attachment of the hat rails. Rated current: 13 ATrigger characteristic: BNominal shutdown capacity: 6 kANumber of poles: 3 PNumber of modules: 3AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50/60 HzConnection type: screw technologyTorque: 2,8NmTotal loss power at rated current: 6.7 WDevice life, electrical switching games: 4000Machine life mechanical switching games: 20000Operating temperature: -25 to 60 °CStorage temperature: -25 to 80 °CHeight installed product: 83 mmWide installed product: 52.5 mmDeep installed product: 70 mm