Eltako

Eltako R12-100-24VDC INSTALLATION RELAY
Eltako R12-100-24VDC INSTALLATION RELAY
3-10 days
Switch relays for mounting on support rails DIN-EN 60715 TH35 Rated switching power 16 A/250 W AC or 10 A/400 W AC Number of contacts as closer: 1 TLE: 1 Rated control voltage Us at AC 50 Hz: 24 - W Voltage type for actuation: DC Electromechanical switching relay with manual actuation and switching position display. Switch-on time 100%. Control power requirement 1.9W. Contact distance 3mm. Test voltage Contact/contact 2000W and test voltage control connections/contact 4000W.
€26.23
Eltako S12-100-24VDC POWER SWITCH
Eltako S12-100-24VDC POWER SWITCH
3-10 days
Current surge switches for mounting on support rails DIN-EN 60715 TH35 rated switching power 16 A / 250 W AC or. 10 A / 400 W AC with manual actuation and switching position display mechanical storage of the switching position Number of locks: 1 width in division units: 1 dimensioning switching current: 16 A control voltage 1: 24 - W control voltage type 1: DC installation depth: 55 mm assembly type: DIN rail voltage type of supply voltage: AC supply voltage range: 250 - 250 W Max. Bulb load: 2300 W Max. Lamp load: 2300 VA Max. Fluorescent lamp load (Duo circuit): 2300 VA Max. Fluorescent lamp load (parallel compensated): 500 VA Max. Switching current (cos phi = 0.6): 10 A manual operation possible: Yes Electromechanical power surge switch with manual actuation and switching position display. Switch-on time 100%. 5-6W. Contact distance 3mm. Distance control terminals/contact > 6mm. .
€26.23
Eltako NLZ61NP-230V Restart switch 1 S
Eltako NLZ61NP-230V Restart switch 1 S
3-10 days
After running switch for installation not potential-free 10A/250V AC, stand-by-loss only 0.7 Watt, contact circuit in the zero passage for the protection of the contacts and consumers, state-of-the-art hybrid technology combines the advantages of wear-free electronic control with the high power of special relays, control voltage, supply and switching voltage 230W, follow-up time 1 to 12 minutes, response delay 0 to 12 minutes control voltage 1: 230 - 230 W. Time range from/to: 0 - 12 2. Time range from/to: 12 - 1 function: response and fall delay Number of locks: 1 switching power bulbs: 2000 W supply voltage range: 250 - 250 W installation height: 18 mm rated current at 250 W AC: 10 A switching power fluorescent lamps DUO: 1000 VA 1. Time range unit: minutes/hours 2. Time range unit: seconds/minutes assembly type: Unterputz follow-up switch 230W. 1 lock not potential-free 10A/250V AC. Stand-by-loss only 0.7 Watt. For installation. 45mm long, 45mm wide, 18mm deep. Contact circuit in the zero passage to protect the contacts and consumers. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. Control voltage, supply and switching voltage 230W. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. After installation, wait for the automatic short synchronization before the switched consumer is placed on the network. Adjustable with the upper rotary switch for 1 to 12 minutes. Response delay 0 to 12 minutes with the lower rotary switch adjustable. Function: With the closing of the control contact (light switch), the response delay AV (if not set 0) begins, at whose end the fan is switched on wi
€42.19
Eltako FT55-rw radio button pure white
Eltako FT55-rw radio button pure white
3-10 days
Radio sensor, 80 x 80 mm outside, frame internal dimensions 55 x 55 mm, 15 mm high. Creates the energy for radio telegrams even at key pressure, therefore without connection line and no stand-by loss. Radio sensor, 80x80mm outside, frame internal dimensions 55x55mm, 15mm high. Creates the energy for radio telegrams even when pressing a button, therefore without connecting line and no stand-by loss. Included are the frame R, a rocker W55, a double rocker DW55 (all the same color), a fastening frame BRF, the holding plate HP, the radio module and an adhesive film. Radio buttons with a rocker can send two, radio buttons with double rocker can send four evaluateable signals. The holding plate can be screwed onto a flat surface or glued to the wall, to glass or to furniture by means of the attached adhesive film. The sleeves present in the can are used for screw fastening via a 55mm switch box. From work, the double rocker is locked onto the radio module. If these are to be exchanged for the large rocker, then pull the rocker halves forward and do not bend towards the center. Then the large rocker snaps on in such a way that its markings 0 and I correspond to the radio module on the rear side. When glued, first attach the set holding plate with frame and fastening frame - with the latches on top and bottom. Then the set radio module with rocker - marking 0 on the back always up - snap in. Color: pure white
€55.29
Eltako FSB14 RS485 bus actuator
Eltako FSB14 RS485 bus actuator
3-10 days
Radio switch for mounting on support rail DIN-EN 60715 TH35, for shading elements and roller shutters, 2 channels for 2 230 V motors, 2+2 closer 4A/250 V AC, potential-separated from supply voltage 12 V, bidirectional, stand-by-loss only 0.1 Watt, connection to the supply voltage 12 V Eltako-RS485 bus, the probes can be learned either as a direction sensor or as a universal probe PLE: 1 Max. Number of blind exits: 2 Bus system EIB/KNX: No Bus system Radiobus: Yes Bus system Powernet: No Bus connection included: Yes Bus system LON: No On site/hand operation: Yes With LED display: No Switch actuator shading elements and roller shutters with 2 channels for two 230V motors. 2+2 Locker 4A/250V AC, potential-separated from the supply voltage 12V. Bidirectional. Stand-by loss only 0.1 Watt. Row mounting device for mounting on support rail. Connection to Eltako-RS485-Bus. Cross-wiring bus and power supply with plug-in bridge. Contact circuit in the zero passage for protecting the contacts and motors. A motor is connected to 1, 2 and N, a second motor may be connected to 3, 4 and N. If both relays of the FSB14 are switched on, 0.4 Watt are required. If the supply voltage fails, it is switched off in a defined manner. The probes can be learned either as a directional sensor or as a universal probe: Local control with universal probe: With each pulse, the switching position changes in the order, stop, stop, stop. Local control with directional sensor: The switching position on is activated in a targeted manner with a key pulse at the top. On the other hand, the switching position Ab is selectively activated by means of a pulse at the bottom. Another pulse from one of the two probes immediately interrupts the sequence. Central control dynamic without priority: By means of a control signal of a probe learned as a central control probe without priority, the switching position Up or Down is activated in a targeted manner. Without priority because this function of other tax
€71.69
Eltako R12-100-230V AC INSTALLATION RELAY
Eltako R12-100-230V AC INSTALLATION RELAY
3-10 days
Switching relays for mounting on support rails DIN-EN 60715 TH35 Rated switching power 16 A/250 V AC or 10 A/400 V AC Number of contacts as closer: 1 Voltage type for actuation: AC TLE: 1 Rated control voltage Us at AC 50 Hz: 230 - V Electromechanical switching relay with manual actuation and switching position display. Switch-on time 100%. Control power requirement 1.9W. Contact distance 3mm. Test voltage Contact/contact 2000V and test voltage Control connections/contact 4000V.
€17.82
Eltako WSZ15D-32A MID AC counter MID ge
Eltako WSZ15D-32A MID AC counter MID ge
3-10 days
Electronic AC meter for mounting on support rail DIN-EN 60715 TH35, maximum current 32A, stand-by loss only 0.4 Watt, accuracy class B (1)%, with SO interface TLE: 1 current A: 5(32) Certified: MID calibrated tariff version of the electricity meter: tariff
€74.42
Eltako EUD61NPN-230V Universal Dimming Switch
Eltako EUD61NPN-230V Universal Dimming Switch
3-10 days
Universal Dimming Switch Mounting type: Unterputz Color: blue Operation type: Rotary knob Halogen-free: Yes Composition: other load type: universal Serial dimmer: No Adjunct input: No Luminous accumulator: Yes Applicable with button: Yes Applicable with motion detector: No Applicable with presence detector: No Applicable with timer matt/timer: No Applicable with radio button: No. Power MOSFET up to 400W. Automatic lamp detection. Stand-by loss only 0.1 Watt. Minimum brightness or dimming speed adjustable. With children's room and slumber circuit. For installation. 45mm long, 45mm wide, 18mm deep. Universal dimming switch for lamps up to 400W, depending on the ventilation conditions. Dimmable energy-saving lamps ESL and dimmable 230V LED lamps additionally depend on lamp electronics. Switching in the zero passage with soft-on and soft-out for lamp protection. Control voltage, supply voltage and switching voltage 230V. No minimum load required. Short control commands turn on/off, permanent control changes the brightness up to the maximum value. An interruption of the control changes the dimming direction. The set brightness level remains stored when switching off (memory). In the event of a power failure, the switching position and the brightness stage are stored and is switched on when the supply voltage is returned. Automatic electronic overload protection and overtemperature shutdown. With the upper %Lampe/dim-speed rotary switch can either set the dimming speed or the minimum brightness (fully dimmed). The dimming speed also changes the duration of soft-on and soft-off. During operation, the lower rotary switch determines whether automatic lamp detection is effective
€55.85
Eltako EUD12D-UC power surge dimming switch
Eltako EUD12D-UC power surge dimming switch
3-10 days
Universal Bus Dimming Switch for mounting on DIN-EN 60715 TH35 Power MOSFET up to 400 W, for lamps up to 400 W, depending on the ventilation conditions, dimmable energy saving lamps ESL and dimmable 230 V-LED lamps additionally depending on the lamp electronics, automatic lamp detection, minimum or maximum brightness and dimming speed adjustable, children's room and slumber circuit width. Stand-by loss only 0.3 Watt. Minimum brightness, maximum brightness and dimming speed adjustable. With children's room and slumber circuit. 1 division unit. Universal dimming switch for lamps up to 400W, depending on the ventilation conditions. Dimmable energy-saving lamps and dimmable 230V LED lamps additionally depend on lamp electronics. Up to 3600W with power inputs at terminals X1 and X2. The control inputs are galvanically separated from the supply and switching voltage. Switching in the zero passage with soft-on and soft-out for lamp protection. In the event of a power failure, the switching position and the brightness stage are stored and is switched on when the supply voltage is returned. From 110W control voltage glow lamp current 5ma (not at RTD). Automatic electronic overload protection and overtemperature shutdown. The functions and times are entered according to the user manual with the MODE and SET keys and displayed on the LC display. A key lock is possible.
€71.69
Eltako FMZ61-230V Radio actuator Multi 30100230
Eltako FMZ61-230V Radio actuator Multi 30100230
3-10 days
Radio actuator multifunction power surge switch For installation and AP mounting. 1 lock, potential-free 10 A /250W AC, light bulbs 2000 Watt. Stand-by loss only 0.8 Watt. With the upper rotary knob several different time functions can be selected. 45 mm long, 55 mm wide, 33 mm deep. Radio actuator multifunction time relay 230W. 1 lock potential-free 10A/250V AC, light bulbs 2000 Watt*. Encrypted radio, bidirectional radio and repeater function can be switched on. Stand-by loss only 0.8 Watt. For installation. 45mm long, 45mm wide, 33mm deep. Supply and control voltage locally 230W. If the supply voltage fails, the switching state is maintained. When the supply voltage is recurring, it is switched off in a defined manner. This radio actuator has the most modern hybrid technology we have developed: We have combined the wear-free reception and evaluation electronics with a bistable relay. As a result, there is no coil loss power and no heating as a result even in the switched-on state. After installation, wait for the automatic short synchronization before the switched consumer is placed on the network. In addition to the radio control input via an internal antenna, this radio actuator can also be controlled locally by means of a conventional control probe installed in front of it. A glow lamp current is not permitted. From the manufacturing week 11/14, encrypted sensors can be learned. Bidirectional radio and/or a repeater function can be switched on. Any change in state as well as the central control telegrams received are confirmed with a radio telegram. This radio telegram can be taught in other actuators, the GFVS software and in universal displays. With the upper rotary switch, up to 35 radio buttons can be assigned in the LRN position, one or more central control buttons thereof. Radio window door contacts (FTK) with the function Locker or Open
€104.93
Eltako FSR61-230V radio actuator
Eltako FSR61-230V radio actuator
3-10 days
Radio actuator power surge relays for installation and AP installation, 1 locks potential-free 10 A /250W AC, incandescent lamps 2000 Watt, power surge switches with reverse deceleration, switch-off pre-warning and pushbutton continuous light can be switched on, stand-by loss 0.9 Watt 1 locks potential-free 10A/250V AC, incandescent lamps 2000 Watt, fall delay with switch-off pre-up and pushbutton. Encrypted radio, bidirectional radio and repeater function can be switched on. Stand-by loss only 0.8 Watt. For installation. 45mm long, 45mm wide, 33mm deep. If the supply voltage fails, the switching state is maintained. When the supply voltage is recurring, it is switched off in a defined manner. After installation, wait for the automatic short synchronization before the switched consumer is placed on the network. In addition to the radio control input via an internal antenna, this radio actuator can also be controlled locally by means of a conventional control probe mounted in front of it. A glow lamp current is not permitted. Encoded sensors can be learned. Bidirectional radio and/or a repeater function can be switched on. Each state change and the central control telegrams received are then confirmed with a radio telegram. This radio telegram can be taught in other actuators, the GFVS software and in universal displays. Scene control: A plurality of FSR61 can be switched on or off to form a scene with one of the four control signals of a pushbutton learned as a scene scanner. With the upper rotary switch, up to 35 radio buttons are assigned in the LRN position, one or more central control buttons thereof. Material quality: Thermoplastic Finishing surface: matt Suitable for dimmer: No Suitable for pulse pushers: Yes Suitable for roller shutter switch: No Suitable for switch: Yes In the case: Yes In the tube socket housing: No As module/plate: No button operation: Yes Switch operation
€105.92
Eltako DSZ15D3x80A MID three-phase counter MID gee
Eltako DSZ15D3x80A MID three-phase counter MID gee
3-10 days
Electrical power meter Maximum power 3x80A, Stand-by-loss only 0.5 Watt per path, Row-mounting device for mounting on support rail DIN-EN 60715 TH35 in installation cabinets with protection class IP51, 4 division units = 70 mm wide, 58 mm deep, accuracy class B (1)%, with S0 interface, which measures directly measuring rotary power meter
€175.86
Eltako S09-230VAC power surge switch
Eltako S09-230VAC power surge switch
3-10 days
Switching devices for DIN EN 50022, rated switching power 16 A/250 W AC or 10 A/400 W AC. Current surge switches mechanical storage of the switching position Current surge switches with manual actuation and switching position display. Only 1/2 division unit. 5W. For pulse control. Contact distance 3mm. Width in division units: 0.5 Number of changers: 0 Number of switches: 1 Number of openers: 0 Rated switching current: 16 A Control voltage 1: 230 - 230 W Control voltage type 1: AC Installation depth: 55 mm Function: other assembly type: DIN rail Frequency of control voltage 1: 50 - 50 Hz Voltage type of supply voltage: AC Supply voltage range: 250 - 250 W Max. Fluorescent lamp load (parallel compensated): 500 VA Max. Switching current (cos phi = 0.6): 8 A manual operation possible: Yes
€24.70
Eltako R12-110-230V AC INHALATION RELAY
Eltako R12-110-230V AC INHALATION RELAY
3-10 days
Switching relay for mounting on support rails DIN-EN 60715 TH35 rated switching power 16 A/250 W AC or. 10 A/400 W AC Electromechanical switching relay with manual actuation and switching position display. Switch-on time 100%. Control power requirement 1.9W. Contact distance 3mm. Test voltage Contact/contact 2000W and test voltage control connections/contact 4000W. Number of contacts as locks: 1 Voltage type for actuation: AC Number of contacts as openers: 1 TLE: 1 Rated control voltage Us at AC 50 Hz: 230 - W
€25.24
Eltako P3K12-230V PHASENKONTROL
Eltako P3K12-230V PHASENKONTROL
3-10 days
Design of the electrical connection screw connection, measurement control supply voltage Us at AC 50 Hz 230 ... 400V, measurement control supply voltage Us at AC 60 Hz 230 ... 400V, voltage type for actuation AC, function phase failure detection, width 17.5mm, for optical monitoring of 1 to 3 phases 230 V. Display by three red light-emitting diodes for 230 V AC. Number of contacts as locks: 0 Number of contacts as openers: 0 Type of electrical connection: Screw connection Type of voltage for actuation: AC Number of contacts as changer: 0 Width: 18 mm Height: 58 mm Depth: 58 mm Function Overvoltage detection: No Rated control voltage Us at AC 50 Hz: 230 - 230 V With removable clamps: No Function Phase sequence detection: No Function. Series installation unit with 1 division unit. For optical monitoring of 1 to 3 external conductors 230V. Display with three red light-emitting diodes.
€40.99