Eltako

 Eltako S12-110-230V AC STROMSTOSSCHALTER
Eltako S12-110-230V AC STROMSTOSSCHALTER
3-10 days
Current surge switches for mounting on support rails DIN-EN 60715 TH35 rated switching power 16 A / 250 W AC or. 10 A / 400 W AC with manual actuation and switching position display mechanical storage of the switching position Electromechanical current surge switch with manual actuation and switching position display. Switch-on time 100%. Tax payable 5-6W. Contact distance 3mm. Distance control connections/contact > 6mm. Number of locks: 1 Number of openers: 1 Width in division units: 1 Rated switching current: 16 A Control voltage 1: 230 - W Control voltage type 1: AC Installation depth: 55 mm Installation type: DIN rail Frequency of control voltage 1: 50 - 50 Hz Voltage type of supply voltage: AC Supply voltage range: 250 - 250 W Max. Bulb load: 2300 W Max. Lamp load: 2300 VA Max. Fluorescent lamp load (Duo circuit): 2300 VA Max. Fluorescent lamp load (parallel compensated): 500 VA Max. Switching current (cos phi = 0.6): 10 A manual operation possible: Yes
Eltako EUD12NPN-UC Electric shock dimming switch
Eltako EUD12NPN-UC Electric shock dimming switch
3-10 days
Universal dimming switch for mounting on support rail DIN-EN 60715 TH35 Power MOSFET up to 400 W, for lamps up to 400 W, depending on the ventilation conditions, dimmable energy-saving lamps ESL and dimmable 230 V-LED lamps additionally depending on lamp electronics, automatic lamp detection, minimum or maximum brightness and dimming speed adjustable, children's room and slumber circuit universal dimming switch. Automatic lamp detection. Stand-by loss only 0.1 Watt. Minimum or maximum brightness and dimming speed adjustable. With children's room and slumber circuit. Universal dimming switch, depending on the ventilation conditions. Dimmable energy-saving lamps ESL and dimmable 230V LED lamps additionally depend on lamp electronics. Switching in the zero passage with soft-on and soft-out for lamp protection. Universal control voltage, galvanically isolated from the supply and switching voltage. No minimum load required. Short control commands turn on/off, permanent control changes the brightness up to the maximum value. An interruption of the control changes the dimming direction. The set brightness level remains stored when switching off (memory). In the event of a power failure, the switching position and the brightness stage are stored and is switched on when the supply voltage is returned. From 110W control voltage glow lamp current 5ma. Automatic electronic overload protection and overtemperature shutdown. Width in division units: 1 Number of outputs: 1 Output power from/to: 400 - W Voltage range: 230 - W Power supply usable: Yes Bus system EIB/KNX: No Bus system Radio bus: No Bus system Powernet: No Bus connection included: No Bus system LON: No Other bus systems: without on-site/hand operation: Yes With LED display: Yes Parallel operation possible: No
Eltako GLE GRANDLASEMENT
Eltako GLE GRANDLASEMENT
3-10 days
Base load element resistance block, PTC in a small socket with connection lines, can be used directly in a consumer, a switch or a branch box, it is not able to hold the field-free switch on without additional consumers A basic load is used if consumers cannot be detected due to their capacity, but should cause the mains voltage to be switched on. Basic loads must always go into operation parallel to the associated consumer and be switched off with the same. Higher standby loads can impair or prevent recognition of a basic load. Examples of this: fluorescent lamps, dimmer circuits and electronic transformers. Basic load element GLE PTC in a small sleeve with connection lines can be used directly in a consumer, a switch or a branch can. It is not able to hold the field-free switch on without additional consumers.
Eltako S12-100-230V AC power surge switch
Eltako S12-100-230V AC power surge switch
3-10 days
Current surge switches for mounting on support rails DIN-EN 60715 TH35 rated switching power 16 A / 250 V AC or. 10 A / 400 V AC with manual actuation and switching position display mechanical storage of the switching position Electromechanical current surge switch with manual actuation and switching position display. Switch-on time 100%. 5-6W. Contact distance 3mm. Distance control connections/contact > 6mm. Number of lockers: 1 width in division units: 1 dimensioning switching current: 16 A control voltage 1: 230 - V control voltage type 1: AC installation depth: 55 mm assembly type: DIN rail frequency of control voltage 1: 50 - 50 Hz voltage type of supply voltage: AC supply voltage range: 250 - 250 V Max. Bulb load: 2300 W Max. Lamp load: 2300 VA Max. Fluorescent lamp load (Duo circuit): 2300 VA Max. Fluorescent lamp load (parallel compensated): 500 VA Max. Switching current (cos phi = 0.6): 10 A manual operation possible: Yes
Eltako S91-100-230VAC STROMSTOSS SALTER
Eltako S91-100-230VAC STROMSTOSS SALTER
3-10 days
Power surge switches for can installation and AP mounting with manual actuation and switching position indicator Rated switch power 10 A/250 W AC or 6 A/400 VAC Dimensions: 26 x 50 x 32 mm Number of locks: 1 Rated switch current: 10 A Control voltage 1: 230 - W Mounting depth: 32 mm Mounting type: Power type of supply voltage: AC Supply voltage range: 250 - 250 W Max. Bulb load: 2300 W Max. Lamp load: 2300 VA Max. Fluorescent lamp load (Duo circuit): 2300 VA Max. Fluorescent lamp load (parallel compensated): 500 VA Max. Switching current (cos phi = 0.6): 10 A manual operation possible: Yes Electromechanical power surge switch with manual actuation and switching position display. Switch-on time 100%. 4-5W. Contact distance 2mm.
Eltako ES61-8..230V UC power surge switch UP
Eltako ES61-8..230V UC power surge switch UP
3-10 days
10A/250V AC, incandescent lamps 2000W, no stand-by loss, hybrid technology, either universal control voltage 8..230V UC at control input +A1/-A2 or 230 W with up to 5 ma Glow lamp current at control input (L)/-A2(N) current surge switches UC. 1 lock potential-free 10A/250V AC, light bulbs 2000W. No standby loss. For installation. 45mm long, 45mm wide, 18mm deep. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. Either universal control voltage 8..230V UC at the control input +A1/-A2 or 230W with up to 5ma glow lamp current at the control input with glow lamp symbol (L)/-A2(N). The simultaneous use of two potentials at the tax inputs is not permissible. Very low switching noise. No constant power supply required, therefore no stand-by loss. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. The relay contact can be open or closed during commissioning and synchronizes during the first actuation. If this current surge switch is in a circuit which is monitored with a field-free switch FR12-230V, it does not require an additional base load, but the monitoring voltage of the FR12-230V must be set to max. The electronics have no own power supply and therefore no power consumption in both contact positions. Only during the short control pulse of only 0.2 seconds, the control current, which activates the microcontroller, lets it read the last switching state from its non-volatile memory, switches the bistable relay accordingly in the opposite direction and writes the new switching state back into the memory. Number of contacts as lock: 1 Rated control voltage Us at AC 60 Hz: 250 - W
Eltako DSZ15DE3x80A three-phase counter
Eltako DSZ15DE3x80A three-phase counter
3-10 days
Electricity meter Maximum current 3x80A, series mounting device for mounting on support rail DIN-EN 60715 TH35 in installation cabinets with protection class IP51, accuracy class 1 (1)%, with SO interface, 800 Imp/kWh, it can be connected 1, 2 or 3 external conductors with current consumption up to 80 A, the starting current is 2oma, the N connection must be present
Eltako S12-100-12V AC STROMSTOSSCHALEN
Eltako S12-100-12V AC STROMSTOSSCHALEN
3-10 days
Current surge switches for mounting on support rails DIN-EN 60715 TH35 rated switching power 16 A / 250 W AC or. 10 A / 400 W AC with manual actuation and switching position display mechanical storage of the switching position Number of locks: 1 width in division units: 1 dimensioning switching current: 16 A control voltage 1: 12 - W control voltage type 1: AC installation depth: 55 mm assembly type: DIN rail frequency of control voltage 1: 50 - 50 Hz voltage type of supply voltage: AC supply voltage range: 250 - 250 W Max. Bulb load: 2300 W Max. Lamp load: 2300 VA Max. Fluorescent lamp load (Duo circuit): 2300 VA Max. Fluorescent lamp load (parallel compensated): 500 VA Max. Switching current (cos phi = 0.6): 10 A manual operation possible: Yes Electromechanical power surge switch with manual actuation and switching position display. Switch-on time 100%. 5-6W. Contact distance 3mm. Distance control connections/contact > 6mm. Suitable for connection to an SELV network.
Eltako ESR12NP-230V+UC Electric shock relay
Eltako ESR12NP-230V+UC Electric shock relay
3-10 days
Current surge relays for mounting on support rails DIN-EN 60715 TH35 16A/250V AC not potential-free, control input 230W AC and additional universal control voltage 8 to 230W UC, with rotary switches for the functions ER = switching relays, ES = current surge switches and ESW = current surge switches with reverse deceleration of 2 to 120 minutes plus switchable switch-off warning and push-off light. Relapse delay with switch-off warning and push-button continuous light can be switched on. Stand-by loss only 0.5 Watt. Contact circuit in the zero passage for protecting the contacts and lamps, in particular this extends the service life of energy-saving lamps. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. Control voltage additionally with galvanically separated universal control voltage. Very low switching noise. Precise time setting of the relapse delay RV in the function ESW from 2 to 120 minutes with minute scale. With control LED. This flashes after 15 minutes with blocked probe (not in function ER). At the 230V control input Glow lamp current up to 150ma, regardless of the ignition voltage (not in function ER). In the relay functions suitable for feedback with the switching voltage of a dimming switch. If the supply voltage fails, it is switched off in a defined manner. The current surge switch automatically switches off after the set delay time has expired if the manual out command has not been given. Time range up to 120 minutes adjustable.
Eltako EUD61M-8..230V UC power surge dimmer UP
Eltako EUD61M-8..230V UC power surge dimmer UP
3-10 days
Multifunction universal dimming switch for installation and AP mounting for R, L and C loads up to 400 W, Power MOSFET up to 400 W, dimmable energy saving lamps ESL up to 100 W, depending on the ventilation conditions, automatic lamp detection, standby loss only 0.1 W, minimum brightness adjustable, child's room and slumber circuit, standby loss only 0.1 Watt. Power MOSFET up to 400W. Automatic lamp detection. Stand-by loss only 0.1Watt. Minimum brightness adjustable. With children's room and slumber circuit. For installation. 45mm long, 45mm wide, 18mm deep. Universal dimming switch for lamps up to 400W, depending on the ventilation conditions. Dimmable energy-saving lamps and dimmable 230V LED lamps additionally depend on lamp electronics. Switching in the zero passage with soft-on and soft-out for lamp protection. Universal control voltage 8..230V UC, galvanically isolated from supply and switching voltage 230W. Short control commands turn on/off, permanent control changes the brightness up to the maximum value. An interruption of the control changes the dimming direction. The set brightness level remains stored in the memory functions when switching off. In the on-max functions is always switched on with maximum brightness level. In the event of a power failure, the switching position and the brightness stage are stored and is switched on when the supply voltage is returned. Automatic electronic overload protection and overtemperature shutdown. With the
Eltako TLZ12-8PLUS Stair Time Switch
Eltako TLZ12-8PLUS Stair Time Switch
3-10 days
Number of hours:. Bulb load: 400 W Max. Fluorescent lamp load (parallel compensated): 400 VA stairlight time switch with switch-off warning and pushbutton continuous light can be switched on. Stand-by-loss only 0.7 Watt. With ESL optimization and multifunction. Contact circuit in the zero passage for protecting the contacts and lamps. In particular, this extends the service life of energy-saving lamps. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. After installation, wait for the automatic short synchronization before the switched consumer is placed on the network. In addition, with galvanically separated universal control voltage. Automatic detection of the circuit type. Glow lamp current up to 50ma, depending on the ignition voltage of the glow lamps. Precise time setting 1 to 30 minutes with minute scale. Permanent light switch with the large rotary switch. After a power failure in the function setting
Eltako FR12-230V
Eltako FR12-230V
3-10 days
Field-free switch Self-learning field-free switch, interrupts the power supply after all downstream consumers and thus prevents disturbing electromagnetic fields, self-learning processor instead of setting buttons for the current thresholds, rated switching power 16 A/250 W AC self-learning field-free switch. Self-learning. Stand-by-loss only 0.8 Watt. Modern hybrid technology combines the advantages of wear-free electronic control with high switching power from special relays. The field-free switch interrupts the power supply after disconnection of downstream consumers and thus prevents interfering electromagnetic fields. Up to a current consumption of 200ma, small consumers are allowed which do not prevent field-free switching after larger consumers are switched off. The limit value does not have to be adjusted manually, but is learned by the FR12 using a patented method. Consumers with more than 200ma current consumption are always defined as consumers which are intended to cause the power supply to be switched on. As long as no larger consumer is switched on, the monitored circuit 1-pole remains switched off from the network. Neutral and protective conductors are not switched to prevent an antenna effect. An adjustable DC voltage with low residual ripple is present for monitoring. Therefore, a bridging of the working contact is not permissible and leads to destruction of the device. When a consumer is switched on, the field-free switch switches the monitored outer conductor with a delay of approx. 1 second and the LED lights red. Measurement voltage: 230 W
Eltako NO12-0013x230V network monitoring relays
Eltako NO12-0013x230V network monitoring relays
3-10 days
Power monitoring relay for mounting on support rail DIN-EN 60715 TH35, for monitoring 230 W AC voltage against the zero conductor, drop delay adjustable 0.1 to 8 seconds, draw delay 0.5 s, LED display for applied voltage, with the lower rotary switch on the front side two draw-on or respectively. Relapse voltages are set: U1: 161W drop-back voltage and 185V draw voltage U2: 196W drop-back voltage and 206W draw-on voltage according to. WDE 0100 part 718 network monitoring relay with field monitoring. Stand-by-loss only 0.8 Watt. Mounting unit for mounting on support rail (1TE) For monitoring 230W AC voltage between 1 to 3 external conductors and the neutral conductor and for monitoring the rotary field (rotating in the right) in the rotary switch positions 2ph and 3ph. In the position L1/L2/L3, only the rotary field is monitored, regardless of the mains voltage. Supply voltage L1-N 180-250V/50Hz. If L1 fails, the relay will drop immediately without a relapse delay. With the lower rotary switch on the front side, two draw or. Relapse voltages are set and the number of monitored external conductors must be specified. U1: 161W falling voltage and 185V tightening voltage. U2: 196W falling voltage and 206W tightening voltage according to. WDE 0100, Part 718 (formerly: WDE 0108, Part 1). LED display for correct applied voltage. In case of incorrect polarity or a missing external conductor, the LED flashes quickly. Relapse delay RV with the upper rotary switch adjustable from 0.1 to 8 seconds. While the RV time is running, the LED flashes slowly. Suit delay 0.5s. Maximum device protection 16A. Number of contacts as changer: 1 TLE: 1
Eltako TLZ12D-plus stairlight time switch
Eltako TLZ12D-plus stairlight time switch
3-10 days
Steplight time scale for mounting on support rail DIN-EN 60715 TH35, 16 A/250 V AC not potential-free, incandescent lamps up to 2300 W, ESL and LED lamps up to 200 W, control voltage 230 V and/or 8..230 V UC, switch off pre-warning and pushbutton continuous light, standby loss adjustable only 0.5 Watt. Stand-by-loss only 0.7 Watt. With ESL optimization and multifunction. The functions and times are entered according to the user manual with the MODE and SET keys and displayed digitally on the -LC display. A key lock is possible. Contact circuit in the zero passage for protecting the contacts and lamps. In particular, this extends the service life of energy-saving lamps. The noiseless electronics do not harass the most sensitive ear, unlike many synchronous motors with mechanical transmission. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. After installation, wait for the automatic short synchronization before the switched consumer is placed on the network. Control, supply and switching voltage 230V. In addition with galvanically separated universal control voltage 8..230V UC. For 3- and 4-wire circuits, switchable, with attic lighting at 4-wire circuit. Automatic detection of the circuit type. Glow lamp current up to 50mA, depending on the ignition voltage of the glow lamps. Precise time setting 1 to 99 minutes. Own continuous light button with the protruding button SET in the functions TLZ, ESV, ES and ER. With motion detector control input BM, which converts the input signal into a control pulse in the function TLZ. Width in division units: 1 Relapse delay: 1 - 1 min Function: electronic with multifunction Assembly type: DIN rail Number of locks: 1 Control voltage 1: 230 - 23
Eltako FUD14 RS485 bus actuator universal dimming.
Eltako FUD14 RS485 bus actuator universal dimming.
3-10 days
Universal dimmor for mounting on support rail DIN-EN 60715 TH35, Power MOSFET up to 400 W or. 800 W, automatic lamp detection, bidirectional, stand-by loss only 0.3 Watt, minimum brightness and dimming speed adjustable, with children's room, slumber and light alarm circuit, in addition with light scene control and constant light control, no minimum load, connection to the RS485 interface universal dimming switch, power MOSFET up to 400W. Automatic lamp detection. Bidirectional. Stand-by loss only 0.3 Watt. Minimum brightness and dimming speed adjustable. With children's room, slumber and light alarm. In addition to light scene control and constant light control. Row mounting device for mounting on support rail. Universal dimming switch for lamps up to 400W, depending on the ventilation conditions, dimmable energy saving lamps ESL and dimmable 230V LED lamps additionally depending on the lamp electronics. Switching in the zero passage with soft-on and soft-out for lamp protection. Switching voltage 230V. No minimum load required. The set brightness level remains stored when switching off (memory). In the event of a power failure, the switching position and the brightness stage are stored and is switched on when the supply voltage is returned. Automatic electronic overload protection and overtemperature shutdown. Connection to Eltako-RS485-Bus. Cross-wiring bus and power supply with plug-in bridge. The upper rotary switch LA/LRN is first required for learning and determines during operation whether the automatic lamp recognition should act or special comfort positions. The LED accompanies the learning process according to the user manual and displays control commands by short flashing. Width in division units: 1 Number of outputs: 1 Output power from/to: 400 - W Voltage range: 230 - V Version: Dimmaktor Power added: No Bus system EIB/KNX: No Bus system Radiobus: