Eltako R12-200-24VDC INSTALLATION RELAY
3-10 days
Switching relays for mounting on support rails DIN-EN 60715 TH35 Rated switching power 16 A/250 W AC or 10 A/400 W AC Number of contacts as closer: 2 TLE: 1 Rated control voltage Us at AC 50 Hz: 24 - W Voltage type for actuation: DC Electromechanical switching relay with manual actuation and switching position display. Switch-on time 100%. Control power requirement 1.9W. Contact distance 3mm. Test voltage Contact/contact 2000W and test voltage control connections/contact 4000W.
€34.94
Eltako R12-110-24VDC INSTALLATION RELAY
3-10 days
Switching relay for mounting on support rails DIN-EN 60715 TH35 rated switching power 16 A/250 W AC or. 10 A/400 W AC Electromechanical switching relay with manual actuation and switching position display. Switch-on time 100%. Control power requirement 1.9W. Contact distance 3mm. Test voltage Contact/contact 2000W and test voltage control connections/contact 4000W. Number of contacts as locks: 1 Number of contacts as openers: 1 TLE: 1 Rated control supply voltage Us at AC 50 Hz: 24 - W Voltage type for actuation: DC
€34.94
Eltako R12-110-12VDC INSTALLATION RELAY
3-10 days
Electromechanical switching relay with manual actuation and switching position display. Switch-on time 100%. Control power requirement 1.9W. Contact distance 3mm. Test voltage Contact/contact 2000W and test voltage control connections/contact 4000W. Mounting type: DIN rail Measurement current: 16 A Number of lockers: 1 Number of changers: 0 Number of openers: 1 Width in division units: 1 Max. Fluorescent lamp load (parallel compensated): 500 VA Max. Fluorescent lamp load (Duo circuit): 2300 VA Max. Incandescent lamp load: 2300 W supply voltage range: 230 - 230 W control voltage 1: 12 - 12 W control voltage type 1: DC frequency of control voltage 1: 50 - 50 Hz Max. Fluorescent lamp load: 2300 VA voltage type of supply voltage: DC Max. Switching current (cos phi = 0.6): 10 A Installation depth: 55 mm Function: other
€34.94
Eltako KR09-230VAC COUPLED RELAY
3-10 days
Coupling relay width 9 mm for support rails DIN EN 60715 TH35, switching position indicator with LED. Only 1/2 division unit = 9 mm wide, 55 mm deep. Safe separation according to WDE 0106, part 101 Voltage type for actuation: AC Number of contacts as closer: 1 Rated control voltage Us at AC 50 Hz: 230 - W Coupling relays. No standby loss. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. Control indicator with LED. Only 0.2W. Safe separation according to WDE 0106, part 101, therefore also usable as a coupling relay.
€36.71
Eltako KR09-24VUC
3-10 days
Coupling relay width 9 mm for support rails DIN EN 60715 TH35, switching position indicator with LED. Only 1/2 division unit = 9 mm wide, 55 mm deep. Safe separation according to WDE 0106, part 101 Mounting type: DIN rail Measurement current: 6 A Number of locks: 1 Number of changers: 0 Number of openers: 0 Width in division units: 0.5 Max. Fluorescent lamp load (parallel compensated): 300 VA Max. Luminous lamp load (Duo circuit): 600 VA Max. Incandescent lamp load: 500 W supply voltage range: 250 - 250 W control voltage 1: 24 - 24 W control voltage type 1: AC/DC frequency of control voltage 1: 50 - 50 Hz Max. Luminous lamp load: 600 VA voltage type of supply voltage: AC Max. Switching current (cos phi = 0.6): 2 A Installation depth: 55 mm Function: partially electronic coupling relays. No standby loss. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. Control indicator with LED. Only 0.2W. Safe separation according to WDE 0106, part 101, therefore also usable as a coupling relay.
€36.71
Eltako ETR61NP-230V separation relay
3-10 days
Frequency range: 50 - 50 Hz Nominal voltage: 230 W Mounting type: other central input: Yes No Number of connectable motors: 1 Switching current: 10 A separator relay 230W. 1 lock not potential-free 10A/250V AC. Stand-by loss only 0.5 Watt. For installation. 45mm long, 45mm wide, 18mm deep. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. Control input with internally generated low voltage 24W DC. galvanically separated from the power supply and the working contact (PELV). Therefore, no external low-voltage power supply is required. With two L-terminals and 2 N-terminals for easy and fast installation. Power supply 230W.
€37.78
Eltako ES75-100-12..24V UC POWER SWITCH E
3-10 days
Electronic power surge switches for control voltages of 12-24 W AC and DC (UC), with interconnected transformer for galvanic separation between control and circuit. For bulbs up to 500 W and fluorescent lamps in DUO circuit up to 1000 W. Low switching noise. Electric shock switch for luminaire installation 12..24V UC. 1 lock not potential-free 10A/250V AC. Stand-by-loss only 1 watt. For installation mounting. 85mm long, 40mm wide, 28mm deep. With integrated transformer for galvanic isolation between control circuit and circuit to meet the requirements for low-voltage protection. Control voltage 12 to 24W UC, control current 10ma at 24W. Constant power supply 230W. For bulb and halogen lamp load (for lamps with max. 150W) up to 500W and fluorescent lamps with KWG in DUO circuit up to 1000VA. Fluorescent lamps with KWG parallel compensated 300VA. Temperature at the installation point between -20°C and +50°C. minimum duration/command pause 20/300ms. 4-pin pin housing for plug STOCKO MKF13264-6-0-404, 230V side 6-pin clamping bar with plug terminals, maximum conductor cross-section 2.5qmm. A Stocko plug is attached to any device. Number of locks: 1 Rated current: 10 A Control voltage 1: 12 - 24 W Control voltage type 1: AC/DC Installation depth: 28 mm Function: other assembly type: other voltage type of supply voltage: AC Supply voltage range: 250 - 250 W Max. Bulb load: 500 W Max. Lamp load (Duo circuit): 1000 VA
€44.96
Eltako ER61 UC relay UP
3-10 days
Switching relays for installation and AP mounting potential-free 10A/250V AC, No stand-by loss Universal control voltage 8-230 W UC, bistable relay as working contact, very low switching noise, due to the use of a bistable relay, there is no coil loss power and no heating as a result of switching relay UC. 1 changer potential-free 10A/250V AC, light bulbs 2000W. No standby loss. For installation and AP mounting. 45 mm long, 45mm wide, 18mm deep. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. Universal control voltage 8..230V UC. Very low switching noise. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. The relay contact can be open or closed during commissioning and synchronizes during the first actuation. This relay is not suitable for feedback with the switching voltage of a dimming switch. Use only the relays ESR12DDX-UC, ESR12NP-230V+UC or ESR61NP-230V+UC. The electronics have no own power supply and therefore no stand-by loss. Only when the control contact is closed is the microcontroller which switches the bistable relay in the correct direction. When the control contact is opened or a falling control voltage is switched back. Number of contacts as changer: 1 measurement control supply voltage Us at AC 50 Hz: 8 - 230 W
€45.56
Eltako TLZ61NP-230V Stair Time Switch
3-10 days
Steplight time switch, electronic for installation and AP installation, 10A/250V AC, control voltage 230W AC, Glow lamp current 50ma, with pumps, switch-off warning and pushbutton continuous light, in addition the function: current surge switch with drop-back delay ESW, contact circuit in the zero crossing of the sine wave to the device and lamp-saving stairlight time switch 230W. 1 lock not potential-free 10A/250V AC, incandescent lamps up to 2000W, ESL and LED lamps up to 200W, switch-off warning and push-button continuous light. Stand-by-loss only 0.7 Watt. With ESL optimization.For installation. 45mm long, 45mm wide, 18mm deep. Contact circuit in the zero passage for protecting the contacts and lamps. In particular, this extends the service life of energy-saving lamps. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. After installation, wait for the automatic short synchronization before the switched consumer is placed on the network. Control, supply and switching voltage 230W. Time setting 1 to 12 minutes. Glow lamp current up to 50ma, depending on the ignition voltage of the glow lamps. For 3- and 4-wire circuits, switchable, with attic lighting at 4-wire circuit. Automatic detection of the circuit type. After a power failure, the illumination is switched on again when the time sequence has not yet been completed. When switched off, the lighting flickers approx. 30 seconds before the time sequence beginning and a total of 3 times in shorter time intervals. When the pushbutton permanent light is switched on, it is possible to set for longer than 1 second by means of buttons, which is switched off automatically after 60 minutes or can be switched off with buttons for longer than 2 seconds. If the pushbutton continuous light and the switch-off pre-warning are switched on, the switch-off pre-warning takes place after the switch-off of the continuous light. Become a full or part
€46.15
Eltako ER12-001-8..230V UC relay
3-10 days
Control relays for support rails DIN EN 60715 TH35 switching position indicator by light-emitting diode, low control power requirement, low switching noise, for small currents, low self-heating, with integrated free-wheeling/lowering diode (A1=+, A2=′′), ER12-001-12 ̊230 W UC according to WDE 010, part 101, therefore also used as coupling relay A250. No standby loss. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. Low switching noise. Control indicator with light-emitting diode. Integrated freewheel/leak diode (A1 =+, A2 =−). Safe separation according to WDE 0106, part 101, therefore also usable as a coupling relay. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. The relay contact can be open or closed during commissioning and synchronizes during the first actuation. This relay is not suitable for feedback with the switching voltage of a dimming switch. The electronics have no own power supply and therefore no stand-by loss. Only when the control contact is closed is the microcontroller which switches the bistable relay in the correct direction. When the control contact is opened or a falling control voltage is switched back. TLE: 1 Number of contacts as changer: 1 Rated control voltage Us at AC 50 Hz: 230 - 230 W
€46.75
Eltako NLZ61NP-8..230V UC Relay
3-10 days
Relay relays for installation and AP-assembly follow-up switches, locks not potential-free, follow-up time can be adjusted steplessly up to 12 minutes, contact circuit in the zero passage to protect the contacts and consumers. Rated switching power 10 A/250 W AC control voltage 1: 8 - 230 W control voltage type 1: AC/DC frequency of control voltage 1: 50 - 50 Hz switching power fluorescent lamps parallel: 500 VA 1. Time range from/to: 12 - 0 2. Time range from/to: 12 - 1 function: response and fall delay Number of locks: 1 switching power bulbs: 2000 W supply voltage range: 250 - 250 W installation height: 18 mm rated current at 250 W AC: 10 A switching power fluorescent lamps DUO: 1000 VA 1. Time range unit: minutes/hours 2. Time range unit: seconds/minutes Mounting type: Unterputz. 1 lock not potential-free 10A/250V AC. Stand-by loss only 0.7 Watt. For installation. 45mm long, 45mm wide, 18mm deep. Contact circuit in the zero passage to protect the contacts and consumers. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. Universal control voltage 8..230V UC galvanically isolated from the supply and switching voltage 230W. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. After installation, wait for the automatic short synchronization before the switched consumer is placed on the network. Adjustable with the upper rotary switch for 1 to 12 minutes. Response delay 0 to 12 minutes with the lower rotary switch adjustable. Function: With the closing of the control contact (light switch), the response delay AV (if not set 0) begins at whose end the fan is switched on. After opening the control contact and if a set response delay had already expired, the set
€47.22
Eltako ESR61NP 230V+UC power surge relays UP
3-10 days
Current surge switches for installation and AP mounting control input 230W AC and additional universal control voltage 8 to 230W UC, with a rotary switch for the functions ER = switching relays, ES = current surge switches and ESW = current surge switches with reverse deceleration number of contacts as closers: 1 measurement control voltage Us at AC 50 Hz: 8 - 230W current surge relay 230V+UC. 1 Locker not potential-free 10A/250V AC, incandescent lamps 2000W, fallback delay with switch-off warning and pushbutton continuous light can be switched on. Stand-by loss only 0.7 Watt. For installation. 45mm long, 45mm wide, 18mm deep. Contact circuit in the zero passage for protecting the contacts and lamps, in particular this extends the service life of energy-saving lamps. The most modern hybrid technology combines the advantages of wear-free electronic control with the high power of special relays. By using a bistable relay, there is no coil loss power and no heating as a result even in the switched-on state. After installation, wait for the automatic short synchronization before the switched consumer is placed on the network. Control voltage 230W, in addition with galvanically separated universal control voltage 8..230V UC. Supply and switching voltage 230W. Very low switching noise. Time setting up to 120 minutes in the function ESW. Sensors with a glow lamp current up to 50ma can be connected to the control input with a glow lamp symbol. If the supply voltage fails, it is switched off in a defined manner. If the delay time is set to a minimum in the ESW function, the relapse delay is switched off and the normal current surge switch function ES results. Switchable to the switching relay ER function. In the function ER, no glow lamp current is permissible and should only be used the control input A1-A2. In the function ER also suitable for feedback with the switching voltage of a dimming switch. When switched on