List of products by brand Hager

Hager CDA445D FI circuit breaker 4P 40A 30mAA type A rated current pre-sureable
2-5 days
Rated current: 40 ANumber of poles: 4 PSensitivity: 30 mAType of differential protection: AImpact strength: 4 kVNumber of modules: 4AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50 HzTorque: 2,8NmConnection type: screw technologyTotal loss power under rated current: 11.8 WDevice life, electrical switching games: 2000Machine life mechanical switching games: 4000Connection cross-section with flexible conductor: 16mm2Connection cross section for rigid conductor: 25mm2Operating temperature: -25 to 40 °CStorage temperature: -55 to 70 °CHeight installed product: 83 mmWide installed product: 70 mmDeep installed product: 70 mm
€81.50
Hager CDS440D FI circuit breaker A 40A/4 30mA 250A, QC 4 polig 6kA 40A 30mA Type A QuickConnect
2-5 days
4pin 6kA 40A 30mA Type A QuickConnect Safety switch (FI) according to EN 61008-1, DIN EN 61008-2-1, VDE 0664 Part 10 + 11, QuickConnect - Clamp at the access for railing up to 63A IP2x according to DIN VDE 0106 part 100. Suitable for Additional equipment (mounting) without tool). Connection terminals with Wire insertion protection, external blue test button. All Products with VDE characters. Labeling option directly on the device. Rated current: 40 A Number of poles: 4 P Sensitivity: 30 mA Type of differential protection: A Impact strength: 4 kV Number of modules: 4 AC voltage: 230/400 V Frequency: 50 Hz
€81.65
Hager MCN510 LS switch 10A/1pol+N/C circuit breaker 1 polig+N 6kA C-characteristic 10A 2 modules
2-5 days
Circuit breaker 1polig+N 6kA C-characteristic 10A 2 modules circuit breaker according to DIN VDE 0641 part 11/8.92, IP2x contact protection according to DIN VDE 0106 part 100 with VDE characters. LS with time-reduced thermal Loose for overload protection and electromagnetic Loose for short-circuit protection. Suitable for retrofitting of additional equipment. marking option directly on the device and individual withdrawal from the phase rail composite Unlocking the quick-fit rail mounting. Rated current: 10 A Trigger characteristic: C Nominal shutdown capacity: 6 kA Number of poles: 2 P Number of modules: 2 Operating voltage AC current: 230/400 V Frequency: 50/60 Hz Connection type: screw technology
€13.01
Hager MCN525 LS switch 25A/1pol+N/C circuit breaker 1 polig+N 6kA C-characteristics 25A 2 modules
2-5 days
Circuit breaker 1polig+N 6kA C-characteristic 25A 2 modules circuit breaker according to DIN VDE 0641 part 11/8.92, IP2x contact protection according to DIN VDE 0106 part 100 with VDE characters. LS with time-reduced thermal Loose for overload protection and electromagnetic Loose for short-circuit protection. Suitable for retrofitting of additional equipment. marking option directly on the device and individual withdrawal from the phase rail composite Unlocking the quick-fit rail mounting. Rated current: 25 A Trigger characteristic: C Nominal shutdown capacity: 6 kA Number of poles: 2 P Number of modules: 2 Operating voltage AC current: 230/400 V Frequency: 50/60 Hz Connection type: screw technology
€16.67
Hager MBN625 LS switch 25A/3pol+N/B 6kA
2-5 days
3polig+N 6kA B-Characteristic 25A 4 ModulesCircuit breaker according to DIN VDE 0641 part 11/8.92 , contact protection IP2x according to DIN VDE 0106 part 100 with VDE characters. LS with time-delayed thermal exhaust for overload protection and electromagnetic exhaust for short-circuit protection. Suitable for retrofit installation of additional equipment. Possibility of marking directly on the device and individual removal from the phase rail composite by unlocking the quick attachment of the hat rails. Rated current: 25 ATrigger characteristic: BNominal shutdown capacity: 6 kANumber of poles: 4 PNumber of modules: 4AC voltage: 230/400 VInsulation voltage: 500 VFrequency: 50/60 HzConnection type: screw technologyTorque: 2,8NmTotal loss power at rated current: 10,1 WDevice life, electrical switching games: 4000Machine life mechanical switching games: 20000Operating temperature: -25 to 60 °CStorage temperature: -25 to 80 °CHeight installed product: 83 mmWide installed product: 70 mmDeep installed product: 70 mm
€72.04
Hager MCN640 LS switch 3P+N 6kA C-40A 4M cable protection switch 3 polig+N 6kA C-characteristics 40A 4 modules
2-5 days
Leitungsschutzschalter 3polig+N 6kA C-Charakteristik 40A 4 Module Leitungsschutzschalter nach DIN VDE 0641 Teil 11/8.92 , Beruehrungsschutz IP2x nach DIN VDE 0106 Teil 100 mit VDE Zeichen. LS mit zeitverzoegertem thermischen Ausloeser fuer Ueberlastschutz und elektromagnetischer Ausloeser fuer Kurzschlussschutz. Geeignet zum nachtraeglichen Anbau von Zusatzeinrichtungen. Beschriftungsmöglichkeit direkt am Gerät und Einzelentnahme aus dem Phasenschienenverbund durch Entriegelung der Hutschienenschnellbefestigung. Nennstrom: 40 A Auslösercharakteristik: C Nennabschaltvermögen: 6 kA Polanzahl: 4 P Anzahl Module: 4 Betriebsnennspannung Wechselstrom: 230/400 V Frequenz: 50/60 Hz Anschlussart: Schraubtechnik



Nennstrom:
40 A


Auslösercharakteristik:
C


Nennabschaltvermögen:
6 kA


Polanzahl:
4 P


Anzahl Module:
4


Betriebsnennspannung Wechselstrom:
230/400 V


Isolationsspannung:
500 V


Frequenz:
50/60 Hz


Anschlussart:
Schraubtechnik


Drehmoment:
2,8Nm


Gesamtverlustleistung unter Nennstrom:
16,9 W


Gerätelebensdauer, elektrische Schaltspiele:
4000


Gerätelebensdauer mechanische Schaltspiele:
20000


Betriebstemperatur:
-25 bis 60 °C


Lagerungstemperatur:
-25 bis 80 °C


Höhe installiertes Produkt:
83 mm


Breite installiertes Produkt:
70 mm


Tiefe installiertes Produkt:
70 mm


€96.43
Hager GD213D Kleinverteiler AP,Gamma,2x13TE,IP30,B250xH375xT103mm
2-5 days



Assembly type:
Structure


Number of rows:
2


Width in division units:
13


Material of housing:
Plastic


Protection type (IP):
IP30


Height:
375 mm


Width:
250 mm


Depth:
of 103 mm


Installation depth:
of 103 mm


With transparent lid:
No


Access:
Yes


EMC version:
No


Color:
white


RAL number:
9010


€44.40
Hager GD106N Mini distributor AP,Gamma,1x6TE,o.door,B146xH180xT82mm
2-5 days
Mini distributor IP30 6 space units Mini distributor as micro distributor made of plastic for the installation of row-mounted germs according to the standard DIN 43 880 as protection cover according to BGV A2 for Geraete up to 63 A, 400 V /50 Hz, protection class IP30. For splash mounting with 46 mm barley slot, serially plombable. Mounting type: plasterMaterial of housing: plasticProtection type: IP30Protection class: Protection class IINumber of distribution rows: 1RAL colour number: 9010Number of modules: 6Color: whiteDoor closure type: without closureHeight installed product: 180 mmWide installed product: 146 mmDeep installed product: 82 mm
€12.91
Hager ADG513D FI/LS 1P+N 10kA B- 13A 30mA Type A-G
2-5 days
1P+N 10kA B- 13A 30mA type A-G fault current circuit breaker according to EN 61009-1 and EN 61009-2-1, short-term delayed according to ÖVE E 8601. IP2x contact protection according to DIN VDE 0660 part 514. Suitable for subsequent mounting of additional devices (mount without tool). Connection terminals with wire insertion protection, Bi-Connect terminals below, external blue test button for half-yearly actuation and fault current display. Easy removal from the phase rail composite. All products with ÖVE characters. Labeling option directly on the device. Nominal current: 13 A Trigger characteristic: B Switching capacity Icn AC according to IEC 60898-1: 10 kA type of fault current protection: A G Rated fault current: 30 mA Number of poles: 2 P Number of modules: 2 Rated operating voltage Ue: 230 V
€74.84