Circuit breaker 1polig+N 6kA B-Characteristic 25A 2 Modules Circuit breaker according to DIN VDE 0641 part 11/8.92 , contact protection IP2x according to DIN VDE 0106 part 100 with VDE characters. LS with time-delayed thermal exhaust for overload protection and electromagnetic exhaust for short-circuit protection. Suitable for retrofit installation of additional equipment. Possibility of marking directly on the device and individual removal from the phase rail composite by unlocking the quick attachment of the hat rails.Rated current:25 ATrigger characteristic:BNominal deactivation capacity:6Number of poles:2 PNumber of modules:2AC voltage:OF 230/400 VInsulation voltage:500 VFrequency:50/60 HzConnection type:Screw technologyTorque:2.8 NmTotal power loss under rated current:6 WDevice life, electrical switching games:4000Machine life mechanical switching games:20000Operating temperature:-25 to 60 °CStorage temperature:-25 to 80 °CHeight installed product:83 mmWide installed product:35 mmDeep Installed Product:70 mm
Circuit breaker 1polig+N 6kA B-Characteristic 6A 2 modules circuit breaker according to DIN VDE 0641 part 11/8.92, IP2x contact protection according to DIN VDE 0106 part 100 with VDE characters. LS with time-reduced thermal Loose for overload protection and electromagnetic Loose for short-circuit protection. Suitable for retrofitting of additional equipment. marking option directly on the device and individual withdrawal from the phase rail composite Unlocking the quick-fit rail mounting. Rated current: 6 A Trigger characteristic: B Nominal shutdown capacity: 6 kA Number of poles: 2 P Number of modules: 2 Operating voltage AC current: 230/400 V Frequency: 50/60 Hz Connection type: screw technology
Circuit breaker 3 polig 6kA C-Characteristic 40A 3 Modules Circuit breaker according to DIN VDE 0641 part 11/8.92 , contact protection IP2x according to DIN VDE 0106 part 100 with VDE characters. LS with time-delayed thermal exhaust for overload protection and electromagnetic exhaust for short-circuit protection. Suitable for retrofit installation of additional equipment. Possibility of marking directly on the device and individual removal from the phase rail composite by unlocking the quick attachment of the hat rails. Nominal current: 40 A Trigger characteristic: C Nominal switching capacity: 6 kA Number of poles: 3 P Number of modules: 3 Operating voltage AC current: 230/400 V Frequency: 50/60 HzRated current:40 ATrigger characteristic:CNominal deactivation capacity:6Number of poles:3 PNumber of modules:3AC voltage:OF 230/400 VInsulation voltage:500 VFrequency:50/60 HzConnection type:Screw technologyTorque:2.8 NmTotal power loss under rated current:16.9 WDevice life, electrical switching games:4000Machine life mechanical switching games:20000Operating temperature:-25 to 60 °CStorage temperature:-25 to 80 °CHeight installed product:83 mmWide installed product:52.5 mmDeep Installed Product:70 mm
Energy meter three-phase, 1 tariff, direct measurement 63A three-phase energy meter for direct measurement of energy consumption up to 63 A with high accuracy (class B). Suitable for use in all network systems. They are equipped with an illuminated digital display that allows the display of energy consumption and power in a resolution of 7 digits including a descending point. A total counter and a partial counter with counter resetting are integrated. The consumption (counter value) can be transmitted remotely by a pulse output. Wiring errors and connection errors are displayed and the measurement data are stored periodically. Connection: Direct connection Operating current: 0.04/63 A Max. Current (I max) of the measuring circuit: 63 A Power consumption: 8.4 VA Number of modules: 4 Frequency: 50/60 Hz
SLS switch 3 polig E-characteristic 50A for DIN rail mounting. SH switch according to E-DIN WDE 0641-21 and standard DIN 43 880 size 2. SLS in 1- or 3-pole design, one-pole switching, with separate contact position display. For direct mounting on a hat rail. The standard (no suggestions) allows the following limitations: for the customer against unintentional or intentional switching; for the installer with a padlock when working in the plant; for the WNB with plombier wire, padlock or special key.
SLS switch 3 polig E-Characteristic 35A for DIN rail mounting. SH switch according to E-DIN WDE 0641-21 and standard DIN 43 880 size 2. SLS in 1- or 3-pole design, one-pole switching, with separate contact position display. For direct mounting on a hat rail. The standard (no suggestions) allows the following limitations: for the customer against unintentional or intentional switching; for the installer with a padlock when working in the plant; for the WNB with plombier wire, padlock or special key.
4 pole 40A for DIN rail/mounting plate Modular 4 pole switch according to DIN EN 60947-3, for switching over under load of 2 low voltage circuits. With safety separation and 3 switching positions I-0-II. Suitable for mounting on hat rail or mounting plate. Rated current: 40 A Rated operating voltage Ue: 380/415 V Number of poles: 4 P Operating temperature: -20 ... 70 °C Connection type: Screwing technology