ABB

ABB PS3/60A Phase rail 3Ph,60Pins,10qmm 2CDL230010R1060
ABB PS3/60A Phase rail 3Ph,60Pins,10qmm 2CDL230010R1060
Out-of-Stock
ABB Phase rails enable secure and economical cross-wiring of automatic fuses, fault current protection devices and other modular installation devices. The following must be taken into account for a correct phase rail selection: terminal type (double terminal or cage terminal), number of terminals (1, 2, 3, 4, 1+N or 3+N), type of device (automatic, fault current protection devices or modular installation devices), combinations of the different types of device, use of automatic fuses with auxiliary switches mounted on the right and the bottom, phase rail connection cross-section (current loadability), number of modules (extractable phases)Product description on the Manufacturer page
ABB ESB40-40-230AC/DC Install.Schütz 4S 230V GHE3491102R0006
ABB ESB40-40-230AC/DC Install.Schütz 4S 230V GHE3491102R0006
Out-of-Stock
4-polige Schütze ESB40 mit 54 mm Baubreite steuern 3-phasige Lasten bis 40 A (Ö-Kontakte bis 30 A) und stehen in unterschiedlichen Kontaktbelegungen und Spulenspannungen zur Verfügung. Sie schalten elektrische Heizgeräte, Warmwasserbereiter, Motoren für Pumpen, Lüftung und sonstige Antriebe ebenso wie Beleuchtungen. Durch eine integrierte Spulenbeschaltung arbeiten sie sowohl mit AC- als auch mit DC-Steuerspannungen. Die Geräte sind deshalb absolut brummfrei und leise beim Schalten. Zubehör wie Hilfsschalter, Plombierkappen und ein Distanzstück ergänzen das Sortiment ESB40 haben Installationsdesign und erfüllen u.a. die Haushaltsnorm EN61095, sie sind daher besonders geeignet für den Verteilereinbau.Produktbeschreibung auf der Herstellerseite
ABB 4TQA605786R0000 FI G 4 40/030-4F - FI-Sch 4P type G -4F 40A, 30mA, 4TE for Austria
ABB 4TQA605786R0000 FI G 4 40/030-4F - FI-Sch 4P type G -4F 40A, 30mA, 4TE for Austria
Out-of-Stock
Safe and reliable: Highest degree of insulation IP20, rear protection, toggle lock, plombable connections, switching position indicator. User-friendly: Inscription field, removal from the collection panel possible. Multifunctional: two-sided mounting option on one device, one device type for all main functions, remote triggers and undervoltage triggers, extension by achievable auxiliary functions. Easy to install: The new hat rail clip allows the removal from the busbar assembly, a device for mounting on both sides, 4-fold combinable, high tightening torque 4.5 Nm, generously dimensioned connection terminals: cable safety switch 35mm2.
ABB F204 A S-40/0,1 FI circuit breaker 4P, type A,40A,100mA,selective 2CSF204201R2400
ABB F204 A S-40/0,1 FI circuit breaker 4P, type A,40A,100mA,selective 2CSF204201R2400
2-10 days
Error current protection switches (RCCBs) offer personal and material protection as well as protection against electrically ignited fires according to DIN VDE 0100-410 and DIN VDE 0100-530. The F200 series fault current protection switches ensure protection against sinusoidal alternating currents and pulsating currents. As well as fault protection (protection in indirect contact), additional protection (with I?n = 30 mA) and fire protection (with I?n = 300 mA). They meet product standards IEC/EN 61008-1, 61008-2-1, 61543 (VDE 0664 10, 11, 30) and F200 A to 100 A UL 1053. Areas of use are household, commercial and industrial applications. The extensive range of accessories offers you everything you need for your installation tasks. Numerous authorisations make the F200 fit for worldwide use. Optimum compromise between safety and operating continuity thanks to the interference resistance against unintentional triggering with impact current strength (stoke current form 8/20 μs) = 5000 A. selectivity with downstream devices with a smaller dimension fault current of, for example, 30 mA (see selectivity tables Catalogue Chapter Technik).Product description on the Manufacturer page
ABB 2CDL240213R1012 PS4/12NA Phase rail 4Ph,12Pins,10qmm
ABB 2CDL240213R1012 PS4/12NA Phase rail 4Ph,12Pins,10qmm
2-7 days
ABB Phase rails enable secure and economical cross-wiring of automatic fuses, fault current protection devices and other modular installation devices. The following must be taken into account for a correct phase rail selection: terminal type (double terminal or cage terminal), number of terminals (1, 2, 3, 4, 1+N or 3+N), type of device (automatic, fault current protection devices or modular installation devices), combinations of the different types of device, use of automatic fuses with auxiliary switches mounted on the right and the bottom, phase rail connection cross-section (current loadability), number of modules (extractable phases)
ABB PS1/57NA Phase rail 1Ph,57Pins,10qmm,N/blue,excl.Pins 2CDL210011R1057
ABB PS1/57NA Phase rail 1Ph,57Pins,10qmm,N/blue,excl.Pins 2CDL210011R1057
2-10 days
ABB Phase rails enable secure and economical cross-wiring of automatic fuses, fault current protection devices and other modular installation devices. The following must be taken into account for a correct phase rail selection: terminal type (double terminal or cage terminal), number of terminals (1, 2, 3, 4, 1+N or 3+N), type of device (automatic, fault current protection devices or modular installation devices), combinations of the different types of device, use of automatic fuses with auxiliary switches mounted on the right and the bottom, phase rail connection cross-section (current loadability), number of modules (extractable phases)Product description on the Manufacturer page
ABB 2CCE160300R0131 E463/3-KB main switch 3S,63A,400VAC
ABB 2CCE160300R0131 E463/3-KB main switch 3S,63A,400VAC
2-7 days
As a main switch between the last overcurrent protective element before the measuring device and the circuit distributor. The main switches can also be used for various other applications. With double-breaking switching contacts and short-circuit strength up to 10 ka with pre-locking In < 63 A; gg
ABB F204 A-63/0,03 FI circuit breaker 4P,type A,63A,30mA 2CSF204101R1630
ABB F204 A-63/0,03 FI circuit breaker 4P,type A,63A,30mA 2CSF204101R1630
2-10 days
Error current protection switches (RCCBs) offer personal and material protection as well as protection against electrically ignited fires according to DIN VDE 0100-410 and DIN VDE 0100-530. The F200 series fault current protection switches ensure protection against sinusoidal alternating currents and pulsating currents. As well as fault protection (protection in indirect contact), additional protection (with I?n = 30 mA) and fire protection (with I?n = 300 mA). They meet product standards IEC/EN 61008-1, 61008-2-1, 61543 (VDE 0664 10, 11, 30) and F200 A to 100 A UL 1053. Areas of use are household, commercial and industrial applications. The extensive range of accessories offers you everything you need for your installation tasks. Numerous authorisations make the F200 fit for worldwide use.Product description on the Manufacturer page
ABB DS201 B16 A30 FI/LS switch 6kA, 1P+N, type A, B 16, 30mA 2CSR255140R1165
ABB DS201 B16 A30 FI/LS switch 6kA, 1P+N, type A, B 16, 30mA 2CSR255140R1165
2-10 days
FI/LS switches (RCBOs) offer personal and property protection as well as protection against electrically ignited fires according to DIN VDE 0100-410 and DIN VDE 0100-530. They ensure protection of single-phase circuits against overload and short-circuit currents, protection with sinusoidal alternating currents and pulsating currents with smooth direct fault current of up to 6 mA against ground. As well as fault protection (protection in indirect contact), additional protection (with I?n = 30 mA) and fire protection (with I?n = 300 mA). They meet product standards IEC/EN 61009-1 (VDE 0664-20), IEC/EN 61009-2-1 (VDE 0664-21). Areas of use are household, commercial and industrial applications. The extensive range of accessories offers you everything you need for your installation tasks. Numerous authorisations make the DS201 fit for worldwide use. Measurement switching capacity according to IEC/EN 61009 Icn = 6 kA. RCBO DS201 A Type A is 1 pole protected (LS), switching 2 poles.Product description on the Manufacturer page
ABB FI-Schalter F204A-40/0,03TG 2CSF204819R1400
ABB FI switch F204A-40/0,03TG 2CSF204819R1400
2-5 days
Error current protection switches (RCCBs) offer personal and material protection as well as protection against electrically ignited fires according to DIN VDE 0100-410 and DIN VDE 0100-530. The F200 series fault current protection switches ensure protection against sinusoidal alternating currents and pulsating currents. As well as fault protection (protection for indirect touching), additional protection (with IΔn ≤ 30 mA) and fire protection (with IΔn ≤ 300 mA). They meet product standards IEC/EN 61008-1, 61008-2-1, 61543 (VDE 0664 10, 11, 30) and F200 A to 100 A UL 1053. Areas of use are household, commercial and industrial applications. The extensive range of accessories offers you everything you need for your installation tasks. Numerous authorisations make the F200 fit for worldwide use.
ABB 2CDS251001R0134 S201-C13 automatic fuse C-Char., 6 kA, 13 A, 1P
ABB 2CDS251001R0134 S201-C13 automatic fuse C-Char., 6 kA, 13 A, 1P
2-7 days
The automatic safety devices of the S 200 series protect cables and cables from overload and short circuit according to DIN VDE 0100-430 and DIN VDE 0100-530. They meet the construction requirements DIN VDE 0641-11 and IEC/EN 60898-1, DIN VDE 0660-101 and IEC/EN60947-2 and UL1077. Their patented connection terminal ensures easy and secure contacting and handling by means of a printing plate. For better visibility conditions during wiring, the connection opening for lines lies above the connection opening for the phase rail. Conductor cross sections up to 35 mm2 can be connected directly to the device via the connection terminal with insulation in protection class IP20. The extensive range of accessories offers you everything you need for your installation tasks. Numerous authorisations make the S 200 fit for worldwide use. Each device is subjected to three-fold intensive tests on quality and performance before delivery.
ABB S201-B13 B-Char., 6 kA, 13 A, 1P 2CDS251001R0135
ABB S201-B13 B-Char., 6 kA, 13 A, 1P 2CDS251001R0135
2-10 days
The automatic safety devices of the S 200 series protect cables and cables from overload and short circuit according to DIN VDE 0100-430 and DIN VDE 0100-530. They meet the construction requirements DIN VDE 0641-11 and IEC/EN 60898-1, DIN VDE 0660-101 and IEC/EN60947-2 and UL1077. Their patented connection terminal ensures easy and secure contacting and handling by means of a printing plate. For better visibility conditions during wiring, the connection opening for lines lies above the connection opening for the phase rail. Conductor cross sections up to 35 mm2 can be connected directly to the device via the connection terminal with insulation in protection class IP20. The extensive range of accessories offers you everything you need for your installation tasks. Numerous authorisations make the S 200 fit for worldwide use. Each device is subjected to three-fold intensive tests on quality and performance before delivery.Product description on the Manufacturer page
ABB LS-Schalter S201-C13NA 2CDS251103R0134
ABB LS switch S201-C13NA 2CDS251103R0134
2-5 days
The automatic safety devices of the S 200 series protect cables and cables from overload and short circuit according to DIN VDE 0100-430 and DIN VDE 0100-530. They meet the construction requirements DIN VDE 0641-11 and IEC/EN 60898-1, DIN VDE 0660-101 and IEC/EN60947-2 and UL1077. Their patented connection terminal ensures easy and secure contacting and handling by means of a printing plate. For better visibility conditions during wiring, the connection opening for lines lies above the connection opening for the phase rail. Conductor cross sections up to 35 mm2 can be connected directly to the device via the connection terminal with insulation in protection class IP20. The extensive range of accessories offers you everything you need for your installation tasks. Numerous authorisations make the S 200 fit for worldwide use. Each device is subjected to three-fold intensive tests on quality and performance before delivery.
ABB 2CDL200001R0001 PS-END end cap for phase rail
ABB 2CDL200001R0001 PS-END end cap for phase rail
2-7 days
ABB Phase rails enable secure and economical cross-wiring of automatic fuses, fault current protection devices and other modular installation devices. The following must be taken into account for a correct phase rail selection: terminal type (double terminal or cage terminal), number of terminals (1, 2, 3, 4, 1+N or 3+N), type of device (automatic, fault current protection devices or modular installation devices), combinations of the different types of device, use of automatic fuses with auxiliary switches mounted on the right and the bottom, phase rail connection cross-section (current loadability), number of modules (extractable phases)