LS switch 16A/3pol+N/CMeasurement switching capacity according to EN 60898:10kAInteractive neutral conductor: yesProtection type (IP):IP20Construction width:70mmSize (according to DIN 43880):4Number of poles:3+NTrigger characteristic:CMeasurement voltage:230/400AC48DCV, Rated current:16AInstallation depth:60mmType of voltage:AC/DCFrequency:50/60Hz
Cable switchMeasurement switching capacity according to EN 60898:10kAInteractive neutral conductor: yesProtection type (IP):IP20Construction width:26,3mmSize (according to DIN 43880):1.5, Number of poles:1+NTrigger characteristic:BMeasurement voltage:230/400AC48DCV, rated current:10AInstallation depth:60mmType of voltage:AC/DCFrequency:50/60Hz
Plug-in for PLS., CLS., PKN., PFIM, PFHM, (with auxiliary switch), any switchgear combinations with or without auxiliary switch possible, only a few components, 2 angle types per rail cross-section for three-phase displacement, common cover profile with end caps for ZV-SS etc. ZV-SS-80AShort-circuit and insulation resistance tested according to IEC/EN 60439-1Measurement current In A: 50Version: flatGalvanized: NoLength mm: 1000Width mm: 8Height mm: 2Flexible: no
Eaton LS switch, 13A, 1p+N, B Cable switchMeasurement switching capacity according to EN 60898:10kAInteractive neutral conductor: yesProtection type (IP):IP20Construction width:26,3mmSize (according to DIN 43880):1.5Number of poles:1+NTrigger characteristic:BMeasurement voltage:230/400AC48DCVMeasurement current:13AInstallation depth:60mmType of voltage:AC/DCFrequency:50/60Hz
Eaton LS switch, 13A/1pol+N/B, 1TE High-quality cable protection switch 1P+N in 1TE for space-saving installationContact position indicator red-greenClamping aid protectionextensive accessory program retrofittableMeasurement currents up to 40 AMeasurement switching capacity 6 kA according to IEC/EN 60898-1Suitable for outdoor use (conveyor and outdoor distributor) up to - 25°Ctrigger characteristic BNumber of poles (total) 2Rated current 13 AMeasurement voltage 230 VMeasurement switching capacity according to EN 60898 6 kAMeasurement switching capacity Icn according to EN 60898 at 230 V 6 kAMeasurement switching capacity according to IEC 60947-2 0 kAMeasurement switching capacity Icu according to IEC 60947-2 at 230 V 0 kAVoltage type ACEnergy limiting class 3Frequency 50 HzInteractive neutral conductor noOvervoltage category 3Level 2Width in division units 1Installation depth 69.5 mmAdditional equipment possible yesProtection (IP) IP20
Eaton LS switch, 16A/1pol+N/B, 1TE High-quality cable protection switch 1P+N in 1TE for space-saving installationContact position indicator red-greenClamping aid protectionextensive accessory program retrofittableMeasurement currents up to 40 AMeasurement switching capacity 6 kA according to IEC/EN 60898-1Suitable for outdoor use (conveyor and outdoor distributor) up to - 25°Ctrigger characteristic BNumber of poles (total) 2Rated current 16 AMeasurement voltage 230 VMeasurement switching capacity according to EN 60898 6 kAMeasurement switching capacity Icn according to EN 60898 at 230 V 6 kAMeasurement switching capacity according to IEC 60947-2 0 kAMeasurement switching capacity Icu according to IEC 60947-2 at 230 V 0 kAVoltage type ACEnergy limiting class 3Frequency 50 HzInteractive neutral conductor noOvervoltage category 3Level 2Width in division units 1Installation depth 69.5 mmAdditional equipment possible yesProtection (IP) IP20
Switching device for the voluntary or tariff current limitation of consumer equipment, version according to EN/IEC 60898-1, EN/IEC 60947, EVU-approbated, easy to switch on from the current customer, setting screw under a sealable cap
Cable switchMeasurement switching capacity according to EN 60898:10kA Interactive neutral conductor:no Protection type (IP):IP20 Construction width:17,5mm Size (according to DIN 43880):1 Number of poles:1 Measurement voltage:230/400AC 48DCV Rated current:10A Installation depth:60mm Voltage type:AC/DC Frequency:50/60Hz
Trigger characteristicCNumber of poles (total)3Number of secured poles3Rated currentA13Measurement voltageV400Measurement switching capacity Icn according to EN 60898 at 230 VKA10Measurement switching capacity Icn according to EN 60898 at 400 VKA10Measurement switching capacity Icu according to IEC 60947-2 at 230 VKA0Measurement switching capacity Icu according to IEC 60947-2 at 400 VKA0Type of voltageACEnergy limiting class3FrequencyHZ50 to 60Interconnecting neutral conductornoSuitable for underground installationnoOvervoltage category3Pollution2Width in division units3Installation depthmmANNEXAdditional equipment possibleyesType of protection (IP)IP20
Eaton Circuit breaker LS switch 16A/3pol/C Trigger characteristic: CNumber of poles (total): 3Number of secured poles: 3Rated current A: 16Measurement voltage V: 400Measurement switching capacity Icn according to EN 60898 at 230 Vk A: 10Measurement switching capacity Icn according to EN 60898 at 400 V kA: 10Measurement switching capacity Icu according to IEC 60947-2 at 230 V kA: 0Measurement switching capacity Icu according to IEC 60947-2 at 400 V kA: 0Type of voltage: ACEnergy limiting class: 3Frequency Hz: 50 - 60Interactive neutral conductor: noSuitable for underground installation: noOvervoltage category: 3Level of pollution: 2Width in division units: 3Installation depth mm: 70.5Additional equipment possible: yesProtection type (IP): IP20